Siren with strobe Strobe Siren: 1.Size:160X117X35mm 2.Operating Voltage: DC 24V/DC12V 3.Working Current: 100150mA 4.Flash Intensity: ≥1.2WS 5.Flash Period: ≤1.5S
Smoke Alarm/gas alarm/fire detector/fire alarm 1.Unit Size:Φ107X44mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤12mA 4.Operation Voltage: DC 9V Battery 5.Alarm Sou
Fire Alarm Control Panel General Specifications 1.Main Supply: 220V AC 50/60Hz+10% 2.Battery Voltage: 24V DC 3.Charging Voltage Protection: Glass Fuse 4.Battery over discharg
Smoke alarm 1.Operating voltage: DC24V/DC12V±10% 2.Temperature range: -10-60oC 3.Humidity range: <95%RH 4.Static current: <10uA 5.Alarm current:
Fire Call point 1.Working Voltage:220VAC 50HZ/24VDC 2.Max.Current:5A 220V 50HZ 8A 24VDC 3.Contact Resistance:≤0.1Ω 4.Working Conditions: Temp.Range :-10
fire call point 1.Working Voltage:220VAC 50HZ/24VDC 2.Max.Current:5A 220V 50HZ 8A 24VDC 3.Contact Resistance:≤0.1Ω 4.Working Conditions: Temp.Range :-10 t
Siren with strobe 1.Size:134X115X48mm 2.Operating Voltage: DC 24V/DC12V 3.Working Current: 100150mA 4.Flash Intensity: ≥1.2WS 5.Flash Period: ≤1.5S 6.Alarm Sound
Smoke Detector 1.Unit Size:Φ103X53mm 2.Working Current: 1-Static Current:≤10μA 2-Alarm Current:≤12mA 4.Operation Voltage: DC 9V Battery 5.Alarm Sound
Alarm Bell 1.Size:Φ150MM 2.Operating voltage: AC220V 3.Working current: ≤100mA 4.Audio Alarm: ≥85d
Gas Exit alarm 1.Operating voltage: DC 19-28V 2.Working current: 100mA 3.Flash frequency: 2S 4.Power rating: 2W 5.The gas discharg light is used for the fire system
gas alarm(co gas) 1. Unit Size:Φ107X44mm 2.Standby Current:≤50uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 min
Co Gas Alarm 1. Unit Size:Φ107X35mm 2.Standby Current:≤50uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 min
Smoke alarm 1.Unit Size:Φ140X41mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤10mA 3.Operation Voltage: DC 9V Battery 4.Alarm Sou
Gas Alarm 1.Size:(L)120×(W)75×(H)42mm 2.Operating voltage: AC 220V/AC 120V/AC 110V 3.Static current: ≤80mA 4.Alarm current: ≤100mA 5.The way
Strobe Siren 1.Rated Voltage: 12 VDC 2.Operating Voltage: 6 To 15VDC 3.Max. Rated Current:180 mA 4.Min.SPL: 110 dB at 12VDC/1m 5.Tone Nature:Warble 6.Housing
strobe siren 1.Size:160X117X35mm; 2.Operating Voltage: DC 24V/DC12V; 3.Working Current: 100-150mA; 4.Flash Intensity: ≥1.2WS; 5.Flash Period: ≤1.5S; 6.Alarm
Smoke Alarm 1.Unit Size:Φ107X35mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤12mA 4.Operation Voltage: DC 9V Battery 5.Alarm Sou
smoke detector 1.Unit Size:Φ140X41mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤12mA 3.Operation Voltage: DC 9V Battery 4.Alarm Sou
Combination Co&Gas Detector 1.Power:Ac110v240v/50hz60hz 2.Alarm Volume:85dB(1m) 3.Alarm Pattern:bi4 times in 4 sec.--1 sec.repeat the pattern 4.Operation Condition: operation t
Alarm Bell 1.Size:Φ150MM 2.Operating voltage: DC24V 3.Working current: ≤25mA 4.Audio Alarm: ≥95dB 5.Waterproof 6.Base Material:Plasti
Smoke Detector 1.Unit Size:Φ107X34mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤12mA 4.Operation Voltage: DC 9V Battery 5.Alarm Sou
Smoke Detector 1.Static current: ≤4.5mA 2.Alarm current: ≤10mA 3. Operating voltage: DC12V to DC30V; 4. Temperature range: -10°C to 60°C 5. Relative h
Co Gas Alarm 1. Unit Size:Φ103X53mm 2.Standby Current:≤50uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 min
Gas Detector 1.Size(L)160×(W)90×(H)37mm 2.Operating voltage: AC220V,DC12V/DC24V 3.Static current: ≤80mA 4.Alarm current: ≤100mA 5.The way of al
Smoke Alarms 1.Unit Size:Φ140X41mm 2.Working Current: 1-Static Current: ≤10μA 2-Alarm Current: ≤12mA 3.Operation Voltage: DC 9V Battery 4.Alarm Sou
Carbon Monoxide Alarm 1. Unit Size:Φ107X44mm 2.Standby Current:≤6uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 minu
Gas Detector 1.Size:(L)120×(W)75×(H)42mm 2.Operating voltage: AC 220V/AC 120V/AC 110V 3.Static current: ≤80mA 4.Alarm current: ≤100mA 5.The way
Carbon Monoxide Alarm 1. Unit Size:Φ107X44mm 2.Standby Current:≤6uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 minu
Carbon Monoxide Alarm 1. Unit Size:Φ107X44mm 2.Standby Current:≤15uA 3.Alarm Density: 30ppm,Alarms Not Activate Within 120minutes 50ppm, Alarms Within 60 90 min
Carbon Monoxide Detector(LCD Displayer) 85 decibel alarm sound. The electrochemical carbon monoxidesensors. Alarm beeps model -- four short alarm. Red, LED shining and panic mode. "The